Technical data

Digital laser measure

GLM 150 C

Article number

‎3 601 K72 F..‎

Measuring range (typical)A)

0.08–150 m

Measuring range (typical, unfavourable conditions)B)

0.08–60 m

Measuring accuracy (typical)A)

±1.5 mm

Measuring accuracy (typical, unfavourable conditions)B)

±3.0 mm

Smallest display unit

0.5 mm

Indirect distance measurement and level

Measuring range

0°–360° (4 × 90°)

Grade measurement

Measuring range

0°–360° (4 × 90°)

Measuring accuracy (typical)C)D)

±0.2°

Smallest display unit

0.1°

General

Operating temperatureE)

–10 °C to +45 °C

Permitted charging temperature range

+5 °C to +40 °C

Storage temperature

–20 °C to +70 °C

Relative air humidity max.

90 %

Max. altitude

2000 m

Pollution degree according to IEC 61010-1F)

2

Laser class

2

Laser type

650 nm, < 1 mW

Divergence of the laser beam

< 1.5 mrad (full angle)

Automatic switch-off after approx.

  • Laser

20 s

  • Measuring tool (without measurement)G)

5 min

Batteries

3 x 1.5 V LR6 (AA)

Weight according to EPTA-Procedure 01:2014

0.23 kg

Dimensions

142 (176) × 64 × 28 mm

Protection rating

IP 54 (dust and splash-proof)

Data transmission

Bluetooth®H)

Bluetooth® 4.2
(Classic and Low Energy)

Operating frequency range

2402–2480 MHz

Max. transmission power

8 mW

A)

For measurements from the front edge of the measuring tool, this applies for high reflectivity of the target (e.g. a white-painted wall), weak backlighting and 25 °C operating temperature. In addition, a deviation of ±0.05 mm/m must be taken into account.

B)

For measurements from the front edge of the measuring tool, this applies for high reflectivity of the target (e.g. a white-painted wall), and strong backlighting. In addition, a deviation of ±0.15 mm/m must be taken into account.

C)

At an operating temperature of 25 °C

D)

After user calibration at 0° and 90°; An additional grade error of ±0.01°/degree to 45° (max.) has to be taken into account. The left-hand side of the measuring tool serves as the reference level for grade measurement.

E)

In continuous measurement mode, the max. operating temperature is +40 °C.

F)

Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

G)

The automatic switch-off time can be adjusted (to two, five, ten minutes or never).

H)

When using Bluetooth® Low Energy devices, it may not be possible to establish a connection depending on the model and operating system. Bluetooth® tools must support the GATT profile.

The serial number (15) on the type plate is used to clearly identify your measuring tool.