Setting Up Formwork
- Mount the measuring tool in the horizontal position on a tripod (26) and set up the tripod outside the formwork area.
- Select rotational operation.
- Secure the laser receiver (24) to a measuring rod (25) with the holder.
- Position the measuring rod on a reference point for the formwork.
- Align the height of the laser receiver on the measuring rod so that the variable laser beam (1) of the measuring tool is indicated as centred.
- Then position the measuring rod with the laser receiver, one after the other, at different test locations on the formwork.

Make sure that the laser receiver remains in the same position on the measuring rod.
- Correct the height of the formwork until the laser beam is indicated as "centred" at all test locations.