Overview
After switching on, the measuring tool checks the horizontal and vertical position and automatically levels out any unevenness within the self-levelling range of approx. ±15 % (±8.5°).
During levelling, the laser is switched off and the slope angle indicator (8) flashes green.
Once levelling is successful, the laser beam is switched on and rotation begins. In the slope angle indicator (8), <0.0%> lights up green when the measuring tool is in a horizontal position and <--> lights up green when the measuring tool is in a vertical position.
If the measuring tool is at a slant of more than 15 % or is positioned differently from the horizontal or vertical position, levelling will not be possible. The halves of <100> flash alternately red in the slope angle indicator (8).
- Reposition the measuring tool and wait for it to re-level.
- If the measuring tool does not level itself automatically after repositioning, briefly press the
button to restart the levelling process.When the measuring tool is levelled in, it continuously checks the horizontal and vertical position. Re-levelling is automatically performed if there are any position changes. To avoid faulty measurements, the laser is switched off during the levelling process. The slope angle indicator (8) flashes green.