Maintenance and Cleaning
Only store and transport the measuring tool in a suitable container, such as the original packaging.
Keep the measuring tool clean at all times. A dirty infrared sensor (22) may impair the measuring accuracy.
When cleaning the measuring tool, ensure that no liquids enter the tool.
Do not attempt to remove dirt from the infrared sensor (22), camera (23), speaker (17) or microphone (14) using sharp objects. Do not wipe over the infrared sensor and camera (risk of scratching).
Please contact an authorised Bosch after-sales service centre if you want to have your measuring tool recalibrated.
If repairs are required, send in the measuring tool in its original packaging.
There are no parts which can be serviced by the user on the measuring tool. Opening the housing shell can destroy the measuring tool.
Replacing the Built-in Coin Cell
The coin cell replacement must be performed by Bosch or by an after-sales service centre authorised to work with Bosch power tools.
- Caution: The coin cell must always be replaced with a coin cell of the same type. There is a risk of explosion.
- Remove and dispose of drained coin cell correctly. Drained coin cell may leak and damage the product or cause personal injury.